text.skipToContent text.skipToNavigation

CAN Board Positioner Input/Output Printed Wire Assembly

2293142
X-Ray
GE HealthCare
GE HealthCare
Adicionar à lista de desejos
Entrar e Comprar
Entrar e Comprar
Por favor selecionar a data
Second Opinion Aprovação Necessária

Insira o seu número de aprovação e submeta para adicionar item (s) no carrinho.

Número de Aprovação

Please enter approval number

OR

Não sabe o seu número de aprovação? Ligue para 800-437-1171
Enter opt 1 para os primeiros três avisos, e tenha o seu ID do Sistema disponível.
Se você adicionar item (s) no carrinho e enviar seu pedido sem o número de aprovação
, a GE irá contactá-lo antes que o seu pedido
seja confirmado para entrega.

Second Opinion Aprovação Necessária

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


O item não está disponível en inventário com a quantidade selecionada. Por favor atualize a quantidade.

Visão geral do produto

The CAN Board Positioner Input/Output Printed Wire Assembly (PWA) is a custom designed circuit board that is used in the Aretha positioner cabinet and other X-ray systems as applicable. The primary function of the CAN positioner I/O board is to provide a signal and CAN communication interface between the positioner cabinet and other peripheral components. The CAN positioner I/O board assembly is comprised of various components including resistor, capacitor, fuse, logic interface, micro peripheral CAN open chip, Field Programmable Gate Array (FPGA), connectors, relays, voltage regulator, surface mount transient voltage suppressor, mounting screws and barcode label. The main functions of the CAN positioner I/O board is to provide communications link between the positioner cabinet and table to the CAN open standard bus Interface with the analog positioner, signal interface for the power assist CAN motion control amplifiers, interface with the legacy table and Spot Film Device (SFD) IDD sensors and switches. The board is mounted vertically against the back wall, inside the positioner cabinet. The maximum permissible board weight is 10 lb or 4.5 kg. The board must be braced to its grounded mounting plate by means of 4 screws or metallic fasteners positioned along the corners of the board and other pressure points. The CAN Positioner I/O board to meet the test, acceptance criteria for the vibration test, classical shock test, and shipping drop test as described in the mechanical environmental test guidelines.

Produtos Compatíveis

Precision 500D

Precision 500D

Robust, digital performance at an efficient dose
It starts with the imaging chain, which features a 12-bit CCD-based camera.Then there’s AutoEx, which automatically adjusts key image-acquisition parameters in real time for optimum quality. Meanwhile, closed-loop Automatic Brightness Control and patented extended Dynamic Range circuitry maintain contrast and minimize blooming.

©2025 GE HealthCare
GE é uma marca registrada da General Electric Company usada sob licença de marca. Todos os direitos reservados.
1) As informações contidas neste material são apresentadas de forma geral, embora se pretenda que não haja dados imprecisos, pode haver diferentes interpretações a esse respeito; Essas informações podem ser restritas em seu país. As configurações e recursos finais do produto podem ser diferentes daqueles mostrados na foto/vídeo;
2) O cliente e/ou fornecedor de cuidados de saúde tem a responsabilidade exclusiva de utilizar o seu próprio julgamento médico e profissional independente na tomada de decisões clínicas, médicas ou financeiras. Nada neste material deve ser utilizado para diagnosticar ou tratar uma doença ou condição de saúde. Consulte um profissional de saúde.